GUIDE SPECIFICATIONS FOR PYRAMIDAL SHAPED SOUND
DIFFUSERS
Section 09840 Acoustical TreatmentPart 1 General
1.1 Work in this area shall be subject to drawings, general conditions, schedules,
addenda and other contract documents.
1.2 The extent of Acoustical Resources, Inc. Pyramidal Shaped Sound
Diffuser Panels are shown on the drawings and in schedules.
1.3 Submit one sample of each type of Sound Diffuser Panel as shown on drawing and
schedules and include appropriate technical information including test data and
maintenance instructions.
1.4 Provide sound diffuser panels from one source.
1.5 Sound Diffuser Panels shall be protected from excessive moisture in
shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with
adequate air circulation. Do not deliver material to building until "wet work"
such as concrete and plaster have been completed and cured to a condition of equilibrium.
1.6 Installation of Sound Diffuser Panels shall not begin until all wet
work is completed. Building shall be properly closed in and under standard occupancy
conditions (temp. of 60 - 85 degrees F. and not more than 80% Relative Humidity).
1.7 The contractor shall be responsible for the examination and
acceptance of all surfaces and conditions prior to the acoustical panel installation.
1.8 Warranty: Panels will be warranted to be free from defects in
material and workmanship, under normal service and use, for a period of one year from the
date of installation.
Part 2 Materials
2.1 Sound Diffuser Panels shall be type: Pyramidal Shaped Ceiling
Series Panels as provided by Acoustical Resources, Inc. / P.O. Box 200504 /
Austin, Texas 78720-0504 / Telephone (512) 259-5858 / FAX (512)259-5850.
2.2 Standard Sound Diffuser panels shall be
constructed of a laminate of one layer of 1 1/2 ounce fiberglass mat saturated with fire
retardant polyester resin with a top coat of white gel-coat
molded in one piece in a special offset, inverted pyramidal shape. (Specified Pyramidal
Shaped Ceiling Diffuser).
Option IA: Internal pyramidal portion of the diffuser shall be lined with 1 1/2"
thick layer of glass fiber batts adhered to it. (Specified Pyramidal Shaped
Diffuser with Internal Absorber (IA).
Option IL: Internal pyramidal portion of diffuser shall be lined with fire retardant
Klegecell board.
(Specified Lined Pyramidal Diffuser (IL).
2.3 Sizes: As shown on drawings. Standard overall size
per panel are:
| P22 = |
23 3/4 x 23 3/4 x 8 h |
| P24 = |
23 3/4 x 47 3/4 x 12 1/2 h |
| P44 = |
47 3/4 x 47 3/4 x 12 1/2 h |
| (Other Sizes and Shapes Available Upon
Request) |
2.4 Panel finish
shall be White Gel-Coat, Lightly Textured.
2.6 Mounting shall be Lay-in into standard
(intermediate) ceiling grid. Where a pyramidal diffuser with internal liner is specified,
the grid shall be rated heavy duty. All grid to be 15/16" width and provided by
others.
2.7 Flammability: All Panel components shall have a
Class "A" (0-25) Flame Spread rating per ASTM E-84.
2.8 Acoustical Ratings: Panels shall have a minimum
Noise Reduction Coefficient (N.R.C.) of .15 in accordance with ASTM test procedures C-423
Type "A" mounting. Gelcoat Finish N.R.C. = .15
Part 3 Execution
3.1 Contractor shall coordinate work of this section with work of other
sections which require interface.
3.2 Install panels in accordance with approved shop drawings following
manufacturer's instructions for installation procedures.
3.3 Clean all panels which may have been soiled or stained during
installation. Carefully follow manufacturer's recommendations, replace any damaged or
permanently soiled panels deemed unacceptable by Architect at no expense to the Owner.
|